1.
After
connecting accessories such as end tools, why can't I use the robotic arm when
I click the corresponding function?
After connecting
the accessories to the robot arm or controller, you need to click
"Refresh" in the software for the accessories to work normally. You
can check whether the accessories are connected normally in the "Operation
Panel" on the right side of the software.
2.
What
should I do when the software prompts an obstacle is detected?
When the desktop
robotic arm encounters resistance, the current of the servo will suddenly
increase. By reading the current value of the servo, you can determine whether
an obstacle has been encountered. You can click the current threshold in
"Settings"-"Obstacle Detection" to adjust the sensitivity
of the robot arm.
3.
The
software shows that the scale jump needs to calibrate the robot arm, but it
prompts that the calibration has failed. What should I do?
Close the
software, shake the arm of the robot arm a few times with your hands, then
restart the controller, and perform the calibration again after the robot arm
is turned on.
4.
What
should I do if the education robot arm is abnormal during movement?
Immediately
press the emergency stop button on the software. After pressing the button, the
robotic arm loses its rigidity and the light band is in red alarm state.
5.
How
do I calibrate the color sensor?
After confirming that the
color sensor is connected to the software, click
"Settings"-"Scene Demo". Place a white disc on the color
sensor, click Calibration, and then place other color discs at will. Click the Photo
to see if the displayed color is the color of the current disc.